<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Tom Camp Inspection Services, LLC &#187; Real Estate Inspector</title>
	<atom:link href="http://www.tomcampinspectionservices.com/tag/real-estate-inspector/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.tomcampinspectionservices.com</link>
	<description>Colorado Springs Certified Professional Inspector &#38; FHA 203K Consultant</description>
	<lastBuildDate>Fri, 06 Jan 2012 17:40:34 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.2.1</generator>
		<item>
		<title>Instructions for Home Occupants Prior to Radon Test</title>
		<link>http://www.tomcampinspectionservices.com/instructions-for-home-occupants-prior-to-radon-test/</link>
		<comments>http://www.tomcampinspectionservices.com/instructions-for-home-occupants-prior-to-radon-test/#comments</comments>
		<pubDate>Mon, 23 Nov 2009 15:08:28 +0000</pubDate>
		<dc:creator>TomCamp</dc:creator>
				<category><![CDATA[Commercial Inspections]]></category>
		<category><![CDATA[Home Inspections]]></category>
		<category><![CDATA[Radon Testing]]></category>
		<category><![CDATA[Colorado Springs]]></category>
		<category><![CDATA[Radon Inspector]]></category>
		<category><![CDATA[Real Estate Inspector]]></category>

		<guid isPermaLink="false">http://www.tomcampinspectionservices.com/?p=487</guid>
		<description><![CDATA[<p>Radon Testing Checklist </p> <p> For reliable test results, follow this Radon Testing Checklist carefully.&#160; Testing for radon is not complicated.&#160; Improper testing may yield inaccurate results and require another test.&#160; Disturbing or interfering with the test device, or with closed-house conditions, may invalidate the test results and is illegal in some states.&#160; If <span style="color:#777"> . . . &#8594; Read More: <a href="http://www.tomcampinspectionservices.com/instructions-for-home-occupants-prior-to-radon-test/">Instructions for Home Occupants Prior to Radon Test</a></span>]]></description>
			<content:encoded><![CDATA[<p><span style="font-size: 18px;"><strong>Radon Testing Checklist</strong><br />
	</span></p>
<p>
	For reliable test results, follow this <a href="http://activerain.com/blogs/www.tomcampinspectionservices.com/additional-services/radon-gas-inspections/" target="_blank">Radon Testing</a> Checklist carefully.&nbsp; Testing for radon is not complicated.&nbsp; Improper testing may yield inaccurate results and require another test.&nbsp; Disturbing or interfering with the test device, or with closed-house conditions, may invalidate the test results and is illegal in some states.&nbsp; If the seller or qualified tester cannot confirm that all items have been completed, take another test.</p>
<p><span style="font-size: 18px;"><br />
	&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <sup><strong>Before Conducting a Radon Test:</strong></sup><br />
	</span></p>
<p>
	&nbsp;&nbsp;&nbsp; &bull;&nbsp;&nbsp;&nbsp; Notify the occupants of the importance of proper testing conditions. Give the occupants written instructions or a copy of this Guide and explain&nbsp;&nbsp;&nbsp; the directions carefully.</p>
<p>
	&nbsp;&nbsp;&nbsp; &bull;&nbsp;&nbsp;&nbsp; Conduct the radon test for a minimum of 48 hours; some test devices have a minimum exposure time greater than 48 hours.</p>
<p>
	&nbsp;&nbsp;&nbsp; &bull;&nbsp;&nbsp;&nbsp; When doing a short-term test ranging from 2-4 days, it is important to maintain closed-house conditions for at least 12 hours before the beginning of the test and during the entire test period.</p>
<p>
	&nbsp;&nbsp;&nbsp; &bull;&nbsp;&nbsp;&nbsp; When doing a short-term test ranging from 4-7 days, EPA recommends that closed-house conditions be maintained</p>
<p>&nbsp;&nbsp;&nbsp; &bull;&nbsp;&nbsp;&nbsp; If you conduct the test yourself, use a qualified radon measurement device and follow the laboratory&#39;s instructions.&nbsp; Your state may be able to&nbsp;&nbsp;&nbsp; provide you with a list of do-it-yourself test devices available from <a href="http://www.reliablelab.com/" target="_blank" title="Pro-Labs">qualified laboratories</a>.&nbsp;</p>
<p>&nbsp;&nbsp;&nbsp; &bull;&nbsp;&nbsp;&nbsp; If you hire someone to do the test, hire only a <a href="http://www.tomcampinspectionservices.com/certifications/" target="_blank" title="Certified Radon Measurment Provider">qualified individual</a>.&nbsp; Some states issue photo identification (ID) cards; ask to see it.&nbsp; The <a href="http://www.tomcampinspectionservices.com/certifications/" target="_self" title="Certified Radon Measurment Provider">tester&#39;s ID number</a>, if available, should be included or noted in the test</p>
<p>&nbsp;&nbsp;&nbsp; &bull;&nbsp;&nbsp;&nbsp; The test should include method(s) to prevent or detect interference with testing conditions or with the testing device itself.</p>
<p>
	&nbsp;&nbsp;&nbsp; &bull;&nbsp;&nbsp;&nbsp; If the house has an active radon-reduction system, make sure the vent fan is operating properly.&nbsp; If the fan is not operating properly, have it (or ask to have it) repaired and then test.</p>
<p style="text-align: center;">
	<span style="font-size: 16px;"><strong>During a Radon Test</strong></span>:</p>
<p>
	Closed-house conditions means keeping all windows closed, keeping doors closed except for normal entry and exit, and not operating fans or other machines which bring in air from outside.&nbsp; Fans that are part of a radon-reduction system or small exhaust fans operating for only short periods of time may run during the test.</p>
<p>
	&nbsp;&nbsp;&nbsp; &bull;&nbsp;&nbsp;&nbsp; Maintain closed-house conditions during he entire time of a short term test, especially for tests shorter than one week in length.</p>
<p>
	&nbsp;&nbsp;&nbsp; &bull;&nbsp;&nbsp;&nbsp; Operate the home&#39;s heating and cooling systems normally during the test. For tests lasting less than one week, operate only air-conditioning units which recirculate interior air.</p>
<p>
	&nbsp;&nbsp;&nbsp; &bull;&nbsp;&nbsp;&nbsp; Do not disturb the test device at any time during the test.</p>
<p>
	&nbsp;&nbsp;&nbsp; &bull;&nbsp;&nbsp;&nbsp; If a radon-reduction system is in place, make sure the system is working properly and will be in operation during the entire radon test.</p>
<p>
	&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <span style="font-size: 16px;"><strong>After a Radon Test:</strong></span></p>
<p>
	&nbsp;&nbsp; &bull;&nbsp;&nbsp;&nbsp; If an elevated level is found, fix the home. Contact a qualified radon-reduction contractor about lowering the radon level.&nbsp; EPA recommends that you mitigate the home when the radon level is 4 pCi/L or more.</p>
<p>
	&nbsp;&nbsp;&nbsp; &bull;&nbsp;&nbsp;&nbsp; Be sure that you or the radon tester can demonstrate or provide information to ensure that the testing conditions were not violated during the testing period.</p>
<p>&nbsp;</p>
<p><img alt="Leo" height="55" src="http://activerain.com/image_store/uploads/7/4/1/4/1/ar125808411214147.jpg" title="Inspections Done Right" width="68" />&nbsp;&nbsp;&nbsp;&nbsp; <a href="http://www.tomcampinspectionservices.com" target="_blank" title="Tom Camp Inspection Services, LLC"><em><strong>Inspections Done Right</strong></em></a></p>
<p><a class="a2a_dd a2a_target addtoany_share_save" href="http://www.addtoany.com/share_save#url=http%3A%2F%2Fwww.tomcampinspectionservices.com%2Finstructions-for-home-occupants-prior-to-radon-test%2F&amp;title=Instructions%20for%20Home%20Occupants%20Prior%20to%20Radon%20Test" id="wpa2a_2"><img src="http://www.tomcampinspectionservices.com/wp-content/plugins/add-to-any/share_save_171_16.png" width="171" height="16" alt="Share"/></a></p>]]></content:encoded>